Carbon steel and Indian Standards
Request an IS 3589 pipe quote. State Fe 330 or Fe 410, outside diameter, wall thickness, manufacturing route and delivery location.
Request a quoteTechnical reference
| Field | Order reference |
|---|---|
| Standard | IS 3589, with the project edition and amendments |
| Product or route | Seamless, ERW or SAW within the ordered grade and scope |
| Critical dimensions and fit | State Fe grade, actual OD, wall, end preparation and internal or external coating |
| Supply enquiry | Confirm sizes, lengths, route, documentation and lead time for your order |
BIS lists an outside diameter scope of 168.3 to 2,540 mm for IS 3589:2001. These are selected OD and wall examples from the Tata Steel rolling chart. Calculated bare mass uses 7,850 kg/m³ and excludes coating, lining and ends.
| Outside diameter (mm) | Wall (mm) | Theoretical bare kg/m |
|---|---|---|
| 219.1 | 5 | 26.40 |
| 219.1 | 6.35 | 33.32 |
| 273.1 | 6.35 | 41.77 |
| 323.9 | 6.35 | 49.73 |
| 406.4 | 6 | 59.25 |
| 508 | 8 | 98.65 |
Reference BIS IS 3589 product manual · Tata Steel pipe dimensions and mass
Use the approved design code and service conditions. The applicable rating depends on material, temperature, minimum effective wall, joint details and the limits of the connected assembly. A schedule or a hydrostatic test result alone cannot establish an operating pressure.
Selected ladle-analysis maxima for Fe 330 and Fe 410. Check the amended Table 2 for the manufacturing route and the full requirements.
| Grade | C max (%) | Mn max (%) | P max (%) | S max (%) |
|---|---|---|---|---|
| Fe 330 | 0.16 | 1.20 | 0.040 | 0.040 |
| Fe 410 | 0.20 | 1.30 | 0.040 | 0.040 |
Reference IS 3589 tables and amendments · BIS IS 3589 product manual
Selected room-temperature values from IS 3589:2001 Table 4. Yield stress is shown on the standard’s design basis. Check the table notes and amended edition for testing and acceptance.
| Grade | Tensile minimum (MPa) | Yield stress (MPa) | Elongation minimum (%) |
|---|---|---|---|
| Fe 330 | 330 | 195 | 20 |
| Fe 410 | 410 | 235 | 18 |
Reference IS 3589 tables and amendments · BIS IS 3589 product manual
Check grade, route, test basis and any required BIS documentation.
| When | What to check |
|---|---|
| Before ordering | Document the required test method, edition and any witness points |
| At delivery | Match the material report and heat or lot identification to the shipment |
Fe 330 and Fe 410 should be quoted on separate lines.
For the enquiry, state Fe grade, actual OD, wall, end preparation and internal or external coating.
IS 3589, with the project edition and amendments · Fe 410, OD 323.9 mm × 6.35 mm wall, bevel and lining per drawing. Add quantity, lengths, delivery city and the required reports.
Ordering guidance
For a steel water or sewage pipe enquiry to IS 3589, provide the specified Fe grade, outside diameter and wall thickness. State the manufacturing route and end preparation if the project specification restricts them.
If a lining, coating, testing or certification requirement appears on the drawing, quote it separately and have the supplier state what is included. Do not assume a quote for Fe 330 meets an Fe 410 requirement because the dimensions match.
Check pricing and availability →
Buyer’s guide
IS 3589 covers steel pipes for water and sewage within its stated scope. Fe 330 and Fe 410 are different steel designations under the standard. Use the project designation and edition, actual outside diameter, wall thickness and length. When the project permits both grades for evaluation, request two named offers so the material and documentation can be checked independently.
Specify the joint detail and end condition. For coated or lined pipe, identify whether the requirement applies inside, outside or both, and give the project coating or lining specification. If a route such as welded or seamless is mandated, state it with the exact project wording. Ask that any deviation is recorded in the technical offer.
Attach drawings for fittings, existing pipe interfaces or ends. List the required test and inspection reports, marking or BIS documentation applicable to the order. If the order has large lengths or phased site deliveries, identify the destination, unloading constraints and sequence so transport and lead times can be compared on the same basis.
| Drawing field | Fe 330 line | Fe 410 line |
|---|---|---|
| Material designation | IS 3589 Fe 330, project edition | IS 3589 Fe 410, project edition |
| Dimensions | State actual OD, wall and lengths | State actual OD, wall and lengths |
| Ends and surface | State joint, coating and lining details | State joint, coating and lining details |
| Inspection | Request records for the offered Fe 330 product | Request records for the offered Fe 410 product |
For a water-line package, state IS 3589 Fe 410, actual OD and wall per drawing, length by piece, joint preparation, coating or lining and delivery sequence. Request Fe 330 on a separate line only when the project allows it.
Fe 410 is a steel designation under IS 3589. Use the ordered OD and wall for geometry and the specified grade for material requirements.
Technical references BIS IS 3589 product manual · BIS IS 1239 Part 1 tube guidance
Prepare your enquiry
| Item | What to send |
|---|---|
| Product details | IS 3589 · Fe 330 or Fe 410 · actual OD · wall · route · coating and tests |
| Delivery | Quantity with units, delivery city and required date if known |
| Acceptance | Required certificates and inspection scope; attach the drawing revision where applicable |
No. Use this page and identify the exact grade on each RFQ line so the quote keeps the requirements separate.
Technical reference: BIS IS 3589 product manual
Related products and standards
Project enquiries
Send your dimensions, quantities and delivery city. Include any inspection or material certificate requirements so they can be quoted against the same line items.
Request a quote → Call +91 99204 92715