Specialist tubing
Enquire for stainless instrumentation tubing. Specify grade, OD, wall, tolerance, surface finish and delivery location.
Request a quoteTechnical reference
| Field | Order reference |
|---|---|
| Standard | A269 for general service where the project specifies it |
| Product or route | Straight or coiled tube for the approved fitting series |
| Critical dimensions and fit | Keep inch and metric ODs separate and confirm fitting-compatible wall and condition |
| Supply enquiry | Confirm sizes, lengths, route, documentation and lead time for your order |
Illustrative drawing sizes. The bore and mass are calculated from the nominal dimensions. Use the project tolerance and confirm the size and route in the quote.
| Tube OD (mm) | Wall (mm) | Nominal bore (mm) | Estimated kg/m at 8,000 kg/m³ |
|---|---|---|---|
| 6 | 1 | 4.00 | 0.13 |
| 6.35 | 0.89 | 4.57 | 0.12 |
| 12 | 1.5 | 9.00 | 0.40 |
Use the approved design code and service conditions. The applicable rating depends on material, temperature, minimum effective wall, joint details and the limits of the connected assembly. A schedule or a hydrostatic test result alone cannot establish an operating pressure.
Reference ASME process piping code B31.3
The grade on the purchase line controls chemistry. Specify the grade with the finished product standard or drawing.
| Check | What to match |
|---|---|
| Grade and specification | TP or UNS on the quotation and material report |
| Heat analysis | Full limits and any stabilising or alloy additions under the ordered edition |
Reference ASTM steel standards
Use the ordered grade, delivery condition and product standard to review the actual tensile, yield, elongation or hardness results required by the order.
| Check | What to verify |
|---|---|
| Condition | Heat treatment or cold-work condition stated for the offered form |
| Acceptance | Project-specified dimensions and relevant test records |
Reference ASTM steel standards
Check the required OD tolerance, ovality, hardness and cleanliness evidence.
| When | What to check |
|---|---|
| Before ordering | Document the required test method, edition and any witness points |
| At delivery | Match the material report and heat or lot identification to the shipment |
6 mm and ¼ in fittings use different tube ODs.
For the enquiry, keep inch and metric ODs separate and confirm fitting-compatible wall and condition.
A269 for general service where the project specifies it · 6 × 1 mm. Add quantity, lengths, delivery city and the required reports.
Ordering guidance
Send actual OD, wall thickness and units. Include the product standard, grade, manufacturing route, tolerance and surface requirements shown on the drawing. Nominal pipe size is not a substitute for actual tube OD.
When the tubing must fit an existing connection, identify its drawing or fitting series and any documented requirements. Ask the project team to confirm the combination rather than assuming every tube of the same OD fits every application.
Check pricing and availability →
Buyer’s guide
Compression fittings are selected for the specified tube OD, which may be inch or metric. A 6 mm tube and a ¼-inch tube have different outside diameters. Copy the unit system from the fitting schedule and confirm the permitted wall, hardness and tube condition with the fitting manufacturer or approved project specification.
For a panel, straight lengths may suit repeated short bends and neat routing. For a long run, state the minimum continuous coil length and whether joints are allowed. Send a take-off by size and length with any requirements for cleaning, capped ends, protective packing or marking by instrument tag.
Use the nominated tube standard and grade, such as A269 where the project specifies it. If wall tolerance, ovality, surface condition or hardness matters at the joint, attach the acceptance criteria. Request documentation against the actual tube size rather than a certificate that covers the alloy family generally.
For a panel build, identify the fitting system, exact OD, wall, grade and cut schedule for each line. Put metric and inch tubing on separate rows and ask that bundles be identified accordingly.
Check the permitted wall range, tube condition and pressure basis in the fitting documentation and project design.
Technical references ASTM A269/A269M scope · ASTM steel standards directory
Prepare your enquiry
| Item | What to send |
|---|---|
| Product details | OD × wall · grade · standard · tolerance · finish · connection reference |
| Delivery | Quantity with units, delivery city and required date if known |
| Acceptance | Required certificates and inspection scope; attach the drawing revision where applicable |
Keep the OD and wall units explicit in the RFQ and check the fitting documentation before converting to metric dimensions.
Technical reference: ASTM steel standards catalogue
Related products and standards
Project enquiries
Send your dimensions, quantities and delivery city. Include any inspection or material certificate requirements so they can be quoted against the same line items.