Forms and finishes
Enquire for stainless pipe or tubing to a project specification. Include design conditions, dimensions, material and inspection needs.
Request a quoteTechnical reference
| Field | Order reference |
|---|---|
| Standard | Project design code plus approved pipe or tube product specification |
| Product or route | Welded piping assembly or tubing with a specified connection system |
| Critical dimensions and fit | State design pressure, temperature, fluid, minimum wall and the exact fitting series |
| Supply enquiry | Confirm sizes, lengths, route, documentation and lead time for your order |
Illustrative drawing sizes. The bore and mass are calculated from the nominal dimensions. Use the project tolerance and confirm the size and route in the quote.
| Tube OD (mm) | Wall (mm) | Nominal bore (mm) | Estimated kg/m at 8,000 kg/m³ |
|---|---|---|---|
| 12 | 1.5 | 9.00 | 0.40 |
| 12 | 2 | 8.00 | 0.50 |
| 12 | 2.5 | 7.00 | 0.60 |
Use the approved design code and service conditions. The applicable rating depends on material, temperature, minimum effective wall, joint details and the limits of the connected assembly. A schedule or a hydrostatic test result alone cannot establish an operating pressure.
Reference ASME process piping code B31.3
The grade on the purchase line controls chemistry. Specify the grade with the finished product standard or drawing.
| Check | What to match |
|---|---|
| Grade and specification | TP or UNS on the quotation and material report |
| Heat analysis | Full limits and any stabilising or alloy additions under the ordered edition |
Reference ASTM steel standards
Read tensile and yield data against the approved grade and condition. Use the design code and the connection limits to establish service conditions.
| Check | What to verify |
|---|---|
| Condition | Heat treatment or cold-work condition stated for the offered form |
| Acceptance | Project-specified dimensions and relevant test records |
Reference ASTM steel standards
Check traceability and the specified acceptance tests for the entire order.
| When | What to check |
|---|---|
| Before ordering | Document the required test method, edition and any witness points |
| At delivery | Match the material report and heat or lot identification to the shipment |
Compare the approved connection ratings alongside the pipe or tube material.
For the enquiry, state design pressure, temperature, fluid, minimum wall and the exact fitting series.
Project design code plus approved pipe or tube product specification · 12 × 1.5 mm. Add quantity, lengths, delivery city and the required reports.
Ordering guidance
Start with the product specification, material grade and dimensions set by the design authority. Include design pressure, design temperature and the applicable code as context for the quotation; grade or schedule alone is not an approved rating.
Identify whether seamless or welded product is required and include applicable wall tolerances, examination or test documents. For an existing system, send the line class or drawing rather than choosing material from a pressure label.
Check pricing and availability →
Buyer’s guide
“High pressure” is a service description. Provide the governing design code, design pressure and temperature, fluid and approved material from the project documents. Identify whether the line is welded pipe, compression tube or a specified high-pressure connection system. Each uses a different dimensional basis, and the permitted tube wall, OD, hardness and finish may depend on the selected fittings.
For a pipe callout, give NPS, schedule or required wall and the end details. For tube, give actual OD and wall, then clarify minimum or nominal wall and applicable tolerance. Send cyclic or transient conditions to the project reviewer if relevant. Use the assembled system’s approved design limits when comparing options.
State the tests, material records, traceability and witness requirements specified on the inspection plan. Agree whether certificates refer to the full supplied length or the original parent tube. If an alternate route or dimension is quoted, capture it as a deviation for technical review.
For a pressure-test skid, submit the fitting series, tube OD and wall, required grade and condition, and the project design pressure and temperature. Attach the approved inspection schedule so the technical and commercial quotes cover the same scope.
Use the approved calculation and fitting or assembly limits. Diameter, tolerances, material condition, temperature and connection details affect the result.
Technical references ASME B36.19 pipe dimensions · ASTM steel standards directory
Prepare your enquiry
| Item | What to send |
|---|---|
| Product details | Design code · pressure and temperature · grade · OD or NPS · wall · inspection scope |
| Delivery | Quantity with units, delivery city and required date if known |
| Acceptance | Required certificates and inspection scope; attach the drawing revision where applicable |
No. Use the approved design and applicable code for the assembled system.
Related products and standards
Project enquiries
Send your dimensions, quantities and delivery city. Include any inspection or material certificate requirements so they can be quoted against the same line items.
Request a quote → Call +91 99204 92715