+91 9920492715 sales@simplexmetal.com
ISO 9001:2015 Certified Exporting Worldwide Since 1995

Stainless steel grades

SS 347H Pipes & Tubes

Request an SS 347H project quote with your standard, pipe schedule or tube wall, quantity and inspection requirements.

Request a quote

Specification

FieldOrder reference
StandardA312 TP347H pipe or A213 TP347H where specified
Product or routeHigh-temperature niobium-stabilised austenitic stainless, UNS S34709
Critical dimensions and fitGroup lengths by boiler or hot-section equipment tag
Supply enquiryConfirm sizes, lengths, route, documentation and lead time for your order

Dimensions and weight

Selected ASME B36.19 dimensions. Schedule columns give nominal wall thickness. Theoretical inside diameter and mass use nominal dimensions, with a reference density of 8,000 kg/m³. Actual mass varies by grade and tolerances.

NPSOD (mm)10S wall (mm)40S wall (mm)80S wall (mm)40S ID (mm)40S kg/m
133.402.773.384.5526.642.55
260.332.773.915.5452.515.54
388.903.055.497.6277.9211.51
4114.303.056.028.56102.2616.38
6168.283.407.1110.97154.0628.80

Reference ASME B36.19 dimensional standard · Tonkin stainless pipe dimensional chart

For tubing, order by actual outside diameter and wall. Drawing example: 38.1 × 3.2 mm tube by circuit and cut length.

Service and pressure basis

Use the approved design code and service conditions. The applicable rating depends on material, temperature, minimum effective wall, joint details and the limits of the connected assembly. A schedule or a hydrostatic test result alone cannot establish an operating pressure.

Reference ASME process piping code B31.3

Chemical composition

Selected chemistry by mass for the A312 pipe designations below. The ordered edition, full element limits and any applicable notes govern acceptance. A dash means the value is omitted here.

GradeUNSC (%)Cr (%)Mo (%)Grade feature
TP347HS347090.04–0.1017–19—Niobium stabilised

Reference ASTM A312/A312M scope · Centravis tubular product catalogue · Alleima high-temperature tubular grades

Mechanical properties

Selected minimum room-temperature tensile and yield strengths for A312 pipe. Elongation acceptance depends on the specimen orientation and applicable thickness basis. For tube orders, apply the nominated tube specification.

GradeTensile minimum (MPa)Yield minimum (MPa)
TP347H515205

Reference ASTM A312/A312M scope · CTS A312 technical reference · Tioga A312 pipe grade reference

Testing and certificates

Check the heat-treatment and supplementary inspection scope before dispatch.

WhenWhat to check
Before orderingDocument the required test method, edition and any witness points
At deliveryMatch the material report and heat or lot identification to the shipment

Application and product comparison

A249 is a separate welded heat-transfer tube specification.

For the enquiry, group lengths by boiler or hot-section equipment tag.

Example request for quotation

A312 TP347H pipe or A213 TP347H where specified · 38.1 × 3.2 mm tube by circuit and cut length. Add quantity, lengths, delivery city and the required reports.

Request a quote

Ordering guidance

Keep 347H visible on the line item

For 347H, quote the H grade, product form and order standard explicitly. Give either pipe NPS and schedule or actual tube OD and wall. A grade-only request leaves too much room for non-comparable offers.

For a project replacement, list any required supplementary testing and documentation alongside the dimension and quantity. Ask the quote to state exceptions before commercial approval.

Check pricing and availability →
Illustration: Three round pipe and tube cross-sections

Buyer’s guide

347H tube and pipe purchase checks for hot equipment

Keep the grade attached to the equipment tag

347H (UNS S34709) is the high-temperature variant of the niobium-stabilised 347 family. Record the exact grade for each equipment tag. If a maintenance order combines 347H hot sections with 347 or other material elsewhere, list them separately so receiving and fabrication teams can identify each line.

Clarify tube route and wall requirements

For boiler or exchanger tubing, check whether the drawing specifies a seamless or welded product standard and whether the ordered wall is minimum or nominal. For a pipe order, use the specified pipe standard and dimensional basis instead. A common chemistry family does not make these manufacturing routes and tolerances interchangeable.

Check the inspection plan against the quotation

Supply any mandatory reports or checks required by the order, including the delivery condition and traceability. Ask the supplier to indicate exceptions or additional inspection lead time in the offer. Where the order is cut into individual lengths, agree markings or bundle labels so the certificate can be traced back after cutting.

Example enquiry

An outage list can identify each 347H tube by equipment tag, product standard, OD, wall basis and finished length. Add the number of pieces and any documented inspection hold point alongside the required arrival date.

Should 347 and 347H be combined under one stock code?

Keep the designations distinguishable unless the plant’s approved material control system expressly addresses the intended use and traceability.

Technical references Alleima high-temperature tube grades · ASTM steel standards directory

Prepare your enquiry

What to put on the purchase list

ItemWhat to send
Product details347H · nominated standard · size basis · wall · quantity · tests
DeliveryQuantity with units, delivery city and required date if known
AcceptanceRequired certificates and inspection scope; attach the drawing revision where applicable

UNS S34709 — 347H is a separate material designation from 347 (S34700).

How do I compare 347H with a quote for 347?

They are different line items unless the project authority approves a substitution. Compare the exact grade and certificate evidence.

Technical reference: Grade designation reference

Project enquiries

Request pricing and availability

Send your dimensions, quantities and delivery city. Include any inspection or material certificate requirements so they can be quoted against the same line items.

Request a quote → Call +91 99204 92715